Transformers

Key Data
P = 90 kW
F = 10–50 kHz
Dimensions: 260 x 110 x 130 mm (L x W x H)
Weight: 9.5 kg

Specials
Cooling systems for inductive components play a key role when designing an optimised custom-specific component. Efficient cooling systems range from water cooling solutions (direct or indirect) and contact cooling to forced air cooling or convection.

 

Key Data
P = 1.5 kW
F = 62.5 kHz
Dimensions: 82 x 60 x 72 mm (L x W x H)
Weight: 0.5 kg

Specials
Using air/solid insulation, the STS high-voltage transformer galvanically isolates a 400 V mains supply to 3.5 kV. Furthermore, the partial discharge free insulation system, supports a long lifetime.

Key Data
P = 0,5–5,5 kW
F = 47–60 kHz
Dimensions: 71 x 71 x 70 mm (L x W x H)
Weight: 1 kg

Specials
The STS production system ensures that items produced in series meet reproducible, high quality standards. Taking into account market-specific standards, this ensures that they function reliably even in highly sensitive fields of application.

Key Data
P = 58 kVA
F = 60-80 kHz
Dimensions: 152 x 129 x 155 mm (L x W x H)
Weight: 9.1 kg

Specials
Using the latest core technologies, power transformers can also be optimised for power density at higher frequencies. The optimised thermal management system implemented in the transformer directs losses directly from the hot spot of the component to the heat sink via the bottom of the housing – as a result, only < 20 % of losses distributed inside the converter.

Key Data
P = 500 kVA
F = 20-50 kHz
Dimensions: 300 x 220 x 400 mm (L x W x H)
Weight: 50 kg

Specials
Through the direct water cooling of the winding, the transformer can be highly efficient cooled. 2,000 W losses at 500 kW transmitting power.

Key Data
P = 650 kW
F = 12 kHz
Dimensions: 670 x 315 x 500 mm (L x W x H)
Weight: 125 kg

Specials
High voltage insulation between the primary and the secondary winding is achieved by ensuring the optimal distances between the coils. This leads to a partial discharge extinction voltage greater than 7 kVac (<200 pC). Cooling system: forced air cooling > 4 m/s.

Key Data
P = 100 kW
F = 25 kHz
Dimensions: 290 x 168 x 125 mm (L x W x H)
Weight: 15.8 kg

Specials
Optimised winding design and tailored core technology permit a low winding capacity in combination with a flat design

Key Data
P = 45 kW
F = 32 kHz
Dimensions: 150 x 90 x 100 mm (L x W x H)
Weight: 5.2 kg

Specials
Thanks to an optimised winding design and tailored core technologies the power density of the transformer can be increased: 8.4 kW/kg!

Key Data
P = 450 W
F = 350 kHz
Dimensions: 60 x 60 x 45 mm (L x W x H)
Weight: 400 g

Specials
High voltage transformer (up to 4.5 kV secondary voltage) at high frequency and high pulse power (4 kW at 1 minute).

contact

We are here
to help

Would you like to find out more about our industry expertise and custom-specific inductive components? Simply get in touch! We would be happy to advise you.